ALUMINIUM ALLOY CONDUCTOR

In stock

AAAC All Aluminium Alloy Conductor Overhead Cable Applications 
AAAC is suitable for overhead line for long span at medium voltage, high voltage and extrahigh
voltage, such as used in the area of mountain, hill,or the place where snow is heavy.
AAAC All Aluminium Alloy Conductor Overhead Cable Operating Temperature:
Max permissible continuous operating temperature of conductor shall not exceed 90°C.
AAAC All Aluminium Alloy Conductor Overhead Cable Standard :
ASTM B399, BS3242, DIN 48201,IEC61089, GB/T1179, AS 1531or other standards required by customers.

Compare

AAAC All Aluminium Alloy Conductor Overhead Cable Construction:
AAAC is stranded concentrically by aluminium alloy wires.

AAAC All Aluminium Alloy Conductor Overhead Cable

AAAC All Aluminium Alloy Conductor Overhead Cable Applications 
AAAC is suitable for overhead line for long span at medium voltage, high voltage and extrahigh
voltage, such as used in the area of mountain, hill,or the place where snow is heavy.
AAAC All Aluminium Alloy Conductor Overhead Cable Operating Temperature:
Max permissible continuous operating temperature of conductor shall not exceed 90°C.
AAAC All Aluminium Alloy Conductor Overhead Cable Standard :
ASTM B399, BS3242, DIN 48201,IEC61089, GB/T1179, AS 1531or other standards required by customers.

Mechanical Property of AAAC

Composition Composition Final modulus of elasticity Final modulus
of elasticity
Mpa
Composition Composition Final modulus of elasticity Final modulus
of elasticity
Mpa
Mpa °C Mpa °C
7 62000 23X10-6 61 54000 23X10-6
19 60000 23X10-6 91 52000 23X10-6
37 57000 23X10-6 127 50500 23X10-6

 

Standard: ASTMB-399

Application:
The aluminium alloy conductor have a much higher strength and Its usage is ideal on long spans or under very severe mechanical conditions

Construction:
The aluminium alloy conductors are stranded on cigar and basked stranding machines create layers.
The adjoining layers of conductor are stranded in opposite direction in such way that external! layer is “right-handed”

AAAC ASTMB-399
Code
Name
Stranding
and wire
diameter
Overall
diameter
Weight Nominal
Breaking
load
Max DC
Resistance
At 20°C
Standard
lenght
Type
of
reel
NO./mm MM Kg/km daN St/km M±5%
Akron 7/1.68 5.04 42.7 492 2.1598 3000 PI710
Alton 7/2.12 6.36 68 784 1.3556 2500×2 PI1000
Ames 7/2.67 8.02 108 1245 0.8548 3200 PI1000
Azusa 7/3.37 10.11 172 1984 0.5365 2300 P11000
Anaheim 7/3.78 11.35 217 2393 0.4265 2700 Pi 1120
Amherst 7/4.25 12.75 273 3018 0.3373 2500×2 PI1250
Allianca 7/4.77 14.31 345 3805 0.2678 2000 PI1250
Butte 19/3.26 16.3 437 4876 0.2112 2900 PI1500
Canton 19/3.66 18.3 551 5891 0.1676 3200 P11600
Cairo 19/3.98 19.88 650 6948 0.1417 2600 P11600
Darien 19/4.36 21.79 781 8354 0.1181 2200 PI1600
Elgin 19/4.71 23.54 911 9742 0.1012 2850 PI1800
Fiint 37/3.59 25.16 1035 10821 0.0894 2700 PI1800
Greeley 37/4.02 28.14 1295 13547 0.0713 2050 PI1800,